CATALOGO BURNDY ESPAOL PDF

On Line Catalog. S BURNDY. BURNDY Catalog Number. UPC Number. Description. Status PENETROX A ESPANOL GHS. Literature. For further technical. This may change as we add new tools so here is a link to type in the catalog part # to get the most current information from our website. Burndy Engineering Co., Inc. Burndy Advance catalog data sheet. Thermometers and hydrometers. H-B Instrument Co. ThermoSpray process for hardfacing.

Author: Vudogor Nataxe
Country: Algeria
Language: English (Spanish)
Genre: Marketing
Published (Last): 27 May 2009
Pages: 125
PDF File Size: 13.15 Mb
ePub File Size: 12.83 Mb
ISBN: 513-6-16817-345-7
Downloads: 19981
Price: Free* [*Free Regsitration Required]
Uploader: Daikazahn

Basic rules for selection are:. Must be like material to the conductor. Two edpaol to catwlogo rod minimum, for mechanical. Cable to cable connections can be installed with one bolt, two bolt, or compression means. Cable to steel structure must have 8 in. Heavy duty stacks mechanical only. The reason is closest 5 ft. Performance excellence and long life expectancy are the system s basic design guidelines.

It is a complete system which consists of connectors for grid cross connections, taps, splices, cable to ground rod, ground plates and terminations. E-5 Our irreversible compression ground connectors employ well-proven design principles and technology that have been in existence for over 60 burdy. Connectors are just one component of our Irreversible Compression Ground System.

Installation tooling is also an integral part of this system. BURNDY pioneered the compression connector principle and continues today to be the leader in compression technology. Our tooling package is the most extensive in the industry and affords the user many options.

Meets NEC code, section Material-pure wrought copper extrusions, rod and seamless tubing identical material to the conductor. Completely eliminates the possibility of corrosion due to dissimilar metals.

BURNDY Master Catalog

Heavy duty connector design. All connectors will carry the equivalent or greater current carrying capacity of the conductor burney maintaining high mechanical strength and electrical integrity. Inventories are kept to a minimum and product selection is simplified. Each tooling recommendation has been designed to ensure reliability of the connection. Irreversible compression connectors can be installed in all kinds of weather. Eliminates costly construction budndy and enables the installer to better schedule his job.

May be installed without special training or special tools. Y crimps entire range. Each connection can be made in less than 3 minutes. Each connector is clearly marked with catalog number, conductor size and installation die information.

Easy and accurate identification. Inspection ports are provided to assure proper insertion of the conductor. The die index number is embossed on the connector after completion of the crimp. Facilitates speedy inspection of installed connectors to insure consistently reliable and sound connections. Ensures that all contact surfaces are in the proper condition for installation. Ensures the electrical integrity of the finished connection by inhibiting moisture and contaminates from entering the contact area.

May be used in direct burial or concrete embedded grounding applications. Meets tough industry performance requirements. Allows connection to most sizes of structural steel with no drilling, tapping, eapaol welding.

  MAC FLECKNOE ANALYSIS PDF

Safely installed at low cost. Hot work permits are not required to install in hazardous areas US: Only six connectors and four dies are required to install all combinations from 6 solid through kcmil. Acceptable for direct burial in earth and concrete. Before crimping, both connector elements can be turned on rod diameter D to any desired position. UL96 Listed for Lightning Protection.

Compression Terminals

Provides high bburndy strength on ground rod. Installation Tools, Die Set Cat. No precrimp needed if using S0, P0 or U0 die sets. Polarized die for the PAT series tool.

Clean rust and protective coatings from rebar prior to installation to provide proper ground connection. Precrimping is not required.

An open groove allows ground rod to be connected to a continuous run or tap. The second groove is ctaalogo a tap only. UL Listed for direct burial in earth or concrete. Tap B accepts a tap conductor only One connector style can be used for many applications, reducing number of connectors in inventory Material is high conductivity wrought copper extrusion, identical material to the conductor High-conductivity copper minimizes resistance and voltage drop.

Eliminates the possibility of corrosion due to dissimilar metals System engineered tooling The tooling recommendation has been designed to ensure a reliable, dependable connection every time The die index number is embossed on conductor after completion of crimp Facilitates speedy inspection of installed connectors to insure consistently reliable and dependable connections Prefilled with PENETROX E and individually sealed in clear polyethylene sheet Ensures the electrical integrity of the finished connection by inhibiting moisture and contaminates from entering the contact area.

Maintains long-term high-conductivity UL Listed May be used in direct burial or concrete embedded grounding applications. Accommodates all cable combinations from 6 solid through kcmil.

C cataogo shaped opening permits placing two continuous parallel cables into conductor groove.

What Burndy die is used to crimp an ILSCO CLND-4/ lug? – ILSCO

Acceptable for direct burial in earth or concrete. A B Die Index No. E- Copper Conductor Sol.

Material is high conductivity copper extrusion Minimizes resistance, eliminates corrosion due to dissimilar metals. Accommodates a wide range of copper conductors to ground rod. The catalog numbers shown are for unplated copper connectors for use on copper clad or stainless steel ground rod.

To order electrotin plated connectors for use on galvanized steel ground rod add suffix -TN to the catalog number. The ground rod hole diameter is larger for galvanized steel ground rod in the tin plated connector. Complete die catalog numbers do not always appear on the connector, sometimes it is the die index.

Performance and long life are this connector s basic design espaoo. Material is high conductivity wrought copper extrusion, identical material to the conductor High-conductivity copper minimizes resistance and catslogo drop. Eliminates the possibility of corrosion due to dissimilar metals.

System engineered tooling Each tooling recommendation has been designed to provide a reliable, dependable connection. The die index number is embossed on connector after completion of crimp Facilitates speedy inspection of installed connectors to ensure consistently reliable and dependable connections.

  ELESA GANTER CATALOGUE PDF

Prefilled with PENETROX and individually sealed in clear polyethylene sheet Ensures the electrical integrity of the finished connection by inhibiting moisture and contaminates from entering the contact area. Acceptable for direct burial May be used in direct burial or concrete embedded grounding applications.

Provides quality catalovo to recognized industry NEC standards from an independent party. Each conductor element has an inspection probe hole to ensure proper cable insertion. Each connector has an inspection probe hole to ensure proper cable insertion. Copper Conductor Size Sol. The tabs are easily welded to steel, with two mounting pattern options available.

Master Catalog. Connecting Power to Your World TM

All connection options and necessary hardware are sold separately. Es;aol used when traditional connection methods are not practical, or when temporary grounds are required.

Common applications include large generators, mobile construction site modules, housing structures built in permafrost areas, and in any metal structure requiring a permanent or temporary ground option. Each conductor element has an inspection probe hole and a center stop to ensure proper cable insertion. The ground plates are made of high strength, high-conductivity cast copper alloy body with a pure wrought copper compression element.

In addition to the tapped NEMA size holes and spacing on the face, the plate comes with a tapped hole on the underside for ease of positioning prior to pouring the concrete. This tapped hole may be used to position the grounding plate brndy a threaded rod prior to placement of the concrete.

If other thread is required, add appropriate suffix code to catalog number. Order terminal mounting hardware separately.

Minimum flange depth In. Connector shipped with thread protection studs only. Order TMHG kits separately. Terminal connector to be ordered separately. Kit consists of studs, flat washers, lockwashers and hex nuts. Install a YGHA terminal, flat washer, lockwasher and hex nut onto stud. Tighten and torque to pound-inches. Dimensions shown in i-beam Flange Thickness column reflect the minimum dimensions required on a beam to property install the i-beam connector.

Use TMHG-9 to double stack lugs. Select the proper connector for your specific application. The VERSITAIL eliminates costly disk grinding and the need to expose virgin metal, the welding process burns through the oxidation and scale to establish excellent electrical grounding continuity. Large conductors may be connected using both compression and bolted connectors in potential ground fault applications. The receptacle is connected to the ground grid with HYGROUND compression connectors and finished flush with surface to provide a permanent corrosion proof grounding point.